Best Western Premier NYC Gateway Hotel - Tesla Destination
North Bergen, NJ
SWTCH Energy is a hotel in North Bergen, NJ with 4 Level 2 charging ports up to 8 kW on the SWTCH network. Charging is free. 24 hours daily; for guest use only. Public access. Listing data from NREL, last confirmed January 2026.
8 kW adds roughly 30 miles of range per hour for a typical EV.
Start session on SWTCH network →7.2 kW adds roughly 25 miles of range per hour for a typical EV.
Start session on SWTCH network →For a typical EV (75 kWh battery) charging from 10% to 80%. Real-world times vary with vehicle, temperature, and station load. Estimate for your EV →
No driver check-ins yet. Charged here recently? A one-tap report helps the next driver know what to expect.
Charged here? Tell the next driver how it went:
No reviews yet — be the first to charge here and share your experience.
As of 2024, New Jersey had 225,400 plug-in vehicles registered — 173,800 fully battery-electric (77%) and 51,600 plug-in hybrid (23%). That ranks New Jersey #6 nationally and represents about 3.7% of all US plug-in registrations.
Across 7,352 publicly-listed ports in New Jersey (3,999 Level 2 and 3,347 DC fast), that works out to roughly 30.7 EVs per public port and 51.9 BEVs per DC fast port.
New Jersey's public charging is keeping pace with adoption — but registrations keep climbing. Listing your stations here helps drivers discover charging close to where they already shop, dine, and stay.
Source: AFDC (data from Experian Information Solutions) · See full New Jersey market data →
North Bergen, NJ
North Bergen, NJ
North Bergen, NJ
North Bergen, NJ
Every field returned by the public data sources for this location, including empty values. For developers, AI agents, and curious drivers.
From U.S. DOE AFDC · Public domain
| id | 419861 |
|---|---|
| zip | 07047 |
| city | North Bergen |
| plus4 | — |
| state | NJ |
| ng_psi | — |
| cng_psi | — |
| country | US |
| latitude | 40.7996641 |
| bd_blends | — |
| longitude | -74.022211 |
| open_date | 2025-05-13 |
| rd_blends | — |
| ev_network | SWTCH |
| ev_pricing | Free |
| updated_at | 2026-02-02T23:16:24Z |
| access_code | public |
| cng_has_rng | — |
| lng_has_rng | — |
| lpg_primary | — |
| status_code | E |
| bd_blends_fr | — |
| hy_is_retail | — |
| hy_pressures | — |
| hy_standards | — |
| rd_blends_fr | — |
| station_name | SWTCH Energy |
| ev_other_evse | — |
| ev_pricing_fr | — |
| expected_date | — |
| facility_type | HOTEL |
| nps_unit_name | — |
| station_phone | — |
| cards_accepted | — |
| ev_dc_fast_num | — |
| ev_network_web | https://swtchenergy.com |
| fuel_type_code | ELEC |
| geocode_status | GPS |
| hy_status_link | — |
| street_address | 1707 69th St |
| funding_sources | — |
| owner_type_code | P |
| access_days_time | 24 hours daily; for guest use only |
| e85_blender_pump | — |
| lpg_nozzle_types | — |
| ng_vehicle_class | — |
| related_stations | — |
| cng_dispenser_num | — |
| cng_total_storage | — |
| cng_vehicle_class | — |
| ev_charging_units | [
{
"network": "SWTCH",
"connectors": {
"J1772": {
"power_kw": 7.2,
"port_count": 1
},
"J3271": {
"power_kw": null,
"port_count": 0
},
"TESLA": {
"power_kw": null,
"port_count": 0
},
"CHADEMO": {
"power_kw": null,
"port_count": 0
},
"NEMA515": {
"power_kw": null,
"port_count": 0
},
"NEMA520": {
"power_kw": null,
"port_count": 0
},
"NEMA1450": {
"power_kw": null,
"port_count": 0
},
"J1772COMBO": {
"power_kw": null,
"port_count": 0
}
},
"port_count": 1,
"charging_level": "2",
"funding_sources": []
},
{
"network": "SWTCH",
"connectors": {
"J1772": {
"power_kw": 8,
"port_count": 1
},
"J3271": {
"power_kw": null,
"port_count": 0
},
"TESLA": {
"power_kw": null,
"port_count": 0
},
"CHADEMO": {
"power_kw": null,
"port_count": 0
},
"NEMA515": {
"power_kw": null,
"port_count": 0
},
"NEMA520": {
"power_kw": null,
"port_count": 0
},
"NEMA1450": {
"power_kw": null,
"port_count": 0
},
"J1772COMBO": {
"power_kw": null,
"port_count": 0
}
},
"port_count": 1,
"charging_level": "2",
"funding_sources": []
},
{
"network": "SWTCH",
"connectors": {
"J1772": {
"power_kw": 8,
"port_count": 1
},
"J3271": {
"power_kw": null,
"port_count": 0
},
"TESLA": {
"power_kw": null,
"port_count": 0
},
"CHADEMO": {
"power_kw": null,
"port_count": 0
},
"NEMA515": {
"power_kw": null,
"port_count": 0
},
"NEMA520": {
"power_kw": null,
"port_count": 0
},
"NEMA1450": {
"power_kw": null,
"port_count": 0
},
"J1772COMBO": {
"power_kw": null,
"port_count": 0
}
},
"port_count": 1,
"charging_level": "2",
"funding_sources": []
},
{
"network": "SWTCH",
"connectors": {
"J1772": {
"power_kw": 8,
"port_count": 1
},
"J3271": {
"power_kw": null,
"port_count": 0
},
"TESLA": {
"power_kw": null,
"port_count": 0
},
"CHADEMO": {
"power_kw": null,
"port_count": 0
},
"NEMA515": {
"power_kw": null,
"port_count": 0
},
"NEMA520": {
"power_kw": null,
"port_count": 0
},
"NEMA1450": {
"power_kw": null,
"port_count": 0
},
"J1772COMBO": {
"power_kw": null,
"port_count": 0
}
},
"port_count": 1,
"charging_level": "2",
"funding_sources": []
}
] |
| lng_vehicle_class | — |
| ng_fill_type_code | — |
| restricted_access | Yes |
| access_detail_code | — |
| cng_fill_type_code | — |
| ev_connector_types | J1772 |
| ev_level1_evse_num | — |
| ev_level2_evse_num | 4 |
| access_days_time_fr | — |
| date_last_confirmed | 2026-01-13 |
| ev_renewable_source | — |
| cng_renewable_source | — |
| lng_renewable_source | — |
| cng_total_compression | — |
| ev_workplace_charging | No |
| maximum_vehicle_class | LD |
| rd_max_biodiesel_level | — |
| groups_with_access_code | Public |
| intersection_directions | — |
| e85_other_ethanol_blends | — |
| rd_blended_with_biodiesel | — |
| groups_with_access_code_fr | Public |
| intersection_directions_fr | — |